Block PV ForecastAs a presentation: PV forecast - functions and benefits at a glance, for customer meetings and training (arrow keys to browse, F for full screen).
This control shows how much electricity the photovoltaic system is expected to generate today and on the next three days – as a daily total and hour by hour. For today the yield measured so far is shown alongside; the history compares yield and forecast of past days and months if recording is switched on. The control is only available in the new block design.
Tapping the tile opens the forecast. A small tile only shows today and tomorrow; there the settings are reached via the gear of the forecast. If -.-- is shown instead of a number, no forecast is available yet.
The forecast is retrieved every hour; on the days of the clock change the day has 23 or 25 hours.
The history shows the recording of the controller. It has to be switched on in the settings; without recording the history stays empty.
The gear allows deleting the recording after a confirmation.
The share symbol in the title bar passes on the chart as a picture, just as it is shown: on a PC the picture is then in the clipboard and can also be saved as a PNG file, on Android and iOS the share menu of the device opens. In the settings behind the gear, Export as CSV saves the displayed data as a CSV file, for example for evaluation in Excel: the selected time range, one column per line.
Changed values are only transferred to the controller with Save; the forecast is then recalculated immediately.
| Learn from yield | The forecast compares itself every hour with the measured yield and compensates shading, soiling and deviations of the system. When switched off, the learned state is kept and still applied. Default on. |
| Learning rate | How strongly one hour changes the learning factor, 1 to 50 %. Small = steady but slow; large = follows quickly but varies with the weather. Default 10 %. |
| Adjust forecast | Raises or lowers the forecast permanently by this share, −50 to +50 %, in addition to learning. Default 0 %. |
| Record history | Stores the measured yield and the forecast per hour and per day on the controller. This is the basis of the history. When switched off, an existing recording is kept, only nothing is added. Default off. |
| Keep | How far back the recording reaches, 1 to 60 months (five years). Older values are dropped automatically, so the file does not keep growing. Each year takes up at most about 1.5 MB. Default 24 months. |
Reset learning (via the gear of the forecast) deletes all learned factors after a confirmation; the forecast starts again without correction. Useful after a modification of the system.
This section is intended for the installer of the system.
The control is linked to a block Block PV Forecast: right-click the control and select the block. The roof surfaces are entered at the block. For the measured yield to appear, the block needs an address at the input PV power or Generation meter.
| Text | Name of the tile. Empty = “PV Forecast”. |
| Background, Font | Colours, as long as no style is active. |