Overview Netatmo camera



Integrates a Netatmo camera: Welcome and Indoor (indoor), Presence and Outdoor (outdoor) or the doorbell. Monitoring can be switched on and off, with the Presence also the floodlight and the siren. Detections and rings appear as pulses.

The block Netatmo account queries the events in the event interval, so they arrive with a delay of up to one interval. Events from before the controller started are not reported. The block does not deliver a live picture.

Inputs

UE
Monitoring
Non-zero switches monitoring of the camera on, 0 switches it off. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent.
FL
Floodlight
Presence only: 0 = off, 1 = on, 2 = automatic on motion. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent.
SI
Siren
Presence with siren only: non-zero sounds the siren, 0 stops it. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent.


Outputs

UE
Monitoring
1 = monitoring is switched on.
ER
Reachable
1 = the device is connected to the Netatmo cloud, 0 = Netatmo reports it as unreachable.
PE
Person detected
Pulse of 1 second when the camera detected a person. NA shows the name of a known person.
BW
Motion
Pulse of 1 second on motion.
TI
Animal detected
Pulse of 1 second when an outdoor camera detected an animal.
FZ
Vehicle detected
Pulse of 1 second when an outdoor camera detected a vehicle.
KL
Ring
Pulse of 1 second when the doorbell was rung.
NA
Person name
Name of the person detected last, as set in the Netatmo app. Empty for unknown persons and other events.
ZE
Event time
Time of the last event as text DD.MM.YYYY hh:mm.
BI
Picture URL
Address of the picture of the last event, if Netatmo delivers one. The address is only valid for a limited time.
FL
Floodlight
Presence only: 0 = off, 1 = on, 2 = automatic.
DA
Data current
1 = Netatmo renewed the values within the timeout. 0 = no data since start, account not signed in or timeout expired.


Parameters

Account
Optional. The Netatmo account block used to query this device. The selection is only shown when the project contains several accounts. Not set: the first account in the project.
Select device
Opens the list of devices the account found at Netatmo, filtered to the devices that fit this block. The selection sets device name and device ID. The Studio must be connected to the controller and the account signed in.
Device name
Name of the device at Netatmo, for display only.
Device ID
Netatmo identifier of the device, room or home. Can also be entered manually. Empty: the block delivers no values and shows »Device?«.
Timeout data outdated
If no new data arrives from Netatmo within this time (minutes), »Data current« drops to 0. The other outputs keep their last known value. 0 = never outdated. Default 30 min.